Definition of Surface Roughness Specification and Measurement
On drawings, roughness is shown with a surface texture symbol defined in ISO 21920-1, which replaced ISO 1302. Each value applies to a stated surface and sometimes to a stated lay, meaning the direction of the machining marks. Roughness is measured by tracing a stylus or an optical sensor across the surface, or estimated by comparison with reference plates.
Why This Matters for Your Business
Roughness also matters when the part is coated. A surface that is too smooth gives powder or paint little to hold on to, and one that is too rough can show through a thin film. Please make clear on the drawing whether each value applies before or after coating, since the caster and the coater will otherwise read it differently. Faces with a tight value are usually produced by CNC machining after casting, so the drawing should mark them as machined surfaces.
Related Terms
Ra value first article inspection CNC machining tolerances for die castings shot blasting surface preparation methods polishing powder coating vs. liquid coating for die castingsFAQ
What Ra values can I expect on an aluminum die casting after different finishing operations?
As an approximation, an as-cast surface from a well-maintained die is typically around Ra 1.6 to 3.2 µm (63 to 125 µin), depending on the die polish and the alloy. CNC milling or turning usually gives Ra 0.8 to 3.2 µm, and fine finishing passes can reach about Ra 0.4 µm. Blasting with steel or stainless shot roughens the surface, typically to about Ra 3.2 to 6.3 µm, while glass bead gives a finer result. Polishing, which JoinCast offers with its shot blasting operations, can bring a cast or machined face below Ra 0.4 µm. These ranges vary with media, tooling and position on the part, so it is worth agreeing the value on a sample before production.
How should a supplier measure and record surface roughness on first article parts?
The supplier should measure each specified surface with a stylus profilometer, using the standard cutoff and evaluation lengths, and enter the actual readings in the first article inspection report. A cutoff of 0.8 mm over a 4 mm evaluation length is typical for machined faces, and 2.5 mm over 12.5 mm for rougher cast or blasted faces. Readings should be taken across the lay at several positions, with the instrument's calibration date recorded. It is worth asking how often the check is repeated in production, since inline quality inspection finds drift in die or tool condition before a full batch is affected.
Does specifying a smoother surface finish raise the price of an aluminum die cast part?
Yes, whenever the value cannot be met by the process that already forms that surface. A cast surface smoother than the die naturally gives needs a better die polish and more frequent die maintenance, and a smoother machined face needs slower feeds or an extra pass. Hand polishing adds labor to every part. Medical equipment components often need smooth, easily cleaned surfaces, so the finish is worth discussing at the quotation stage.